Structured Cabling已經成為Data Center design and build的重要課題,隨着Data Center的網絡速度越來越快,Data Center design and build在進行Structured Cabling需要考慮哪些因素?
1.銅纜長度:傳統無源銅纜主要用於連結單個機架內的設備,其距離通常限制在7~10米;而有源銅纜在每端的連接器中安裝電子器件或光學器件,因此能克服大多數物理距離的限制欢迎www.xbaixing.com。
2.線纜屬性:在同等數據速率的情況下,Fiber Optic Cable比銅纜更輕更薄,彎曲半徑更小且不需要屏蔽,因此能提供Data Center design and build更多靈活性小~百~姓~网。
3.冷卻和氣流:大量電纜會降低連接設備的冷區效率和壽命,以及增加設備的功耗,而在這方面更加輕薄的Fiber Optic Cable更具優勢x.b.a.i.x.i.n.g.c.o.m。
4.電磁干擾:銅質電纜的連接器和導體都會產生電磁干擾,而Fiber Optic Cable本身不會發出電磁輻射,此外光學元件的設計和屏蔽要比銅纜更精細,因此從抗電磁干擾來看,Fiber Optic Cable更為優越x+b+a+i+x+i+n+g+c+o+m。
除了上述幾個因素,Data Center design and build在進行Structured Cabling,還需要考慮成本和板載與基於電纜的均衡欢迎www.xbaixing.com。
* * * * * *
創世服務有限公司是一間提供專業數據中心架設公司,擁有一群專業團隊貼心地關注客戶的要求,並提供優質的服務www.xbaixing.com。
想了解更多關於「Data Center design and build在進行Structured Cabling需要考慮哪些因素」的內容,請瀏覽創世官網:http://livservices.com.hk
地址: 香港觀塘鴻圖道37-39號鴻泰工業大廈4樓4室
電話:852-31063235
——————
What factors do Data Center design and build need to consider when doing Structured Cabling?
1. Copper cable length: Traditional passive copper cables are mainly used to connect equipment in a single rack, and the distance is usually limited to 7 to 10 meters; while active copper cables are installed with electronic devices or optical devices in the connectors at each end. Therefore, it can overcome most physical distance limitations.
2. Cable properties: At the same data rate, Fiber Optic Cable is lighter and thinner than copper cable, has a smaller bending radius and does not require shielding, so it can provide more flexibility in Data Center design and build.
3. Cooling and airflow: A large number of cables will reduce the efficiency and life of the cold area of the connected equipment, and increase the power consumption of the equipment, and the thinner and thinner Fiber Optic Cable has advantages in this regard.
4. Electromagnetic interference: The connectors and conductors of copper cables will generate electromagnetic interference, and Fiber Optic Cable itself will not emit electromagnetic radiation. In addition, the design and shielding of optical components are more elaborate than copper cables, so from the perspective of anti-electromagnetic interference , Fiber Optic Cable is more superior.
In addition to the above factors, Data Center design and build is performing Structured Cabling, it also needs to consider the cost and the balance between on-board and cable-based.
* * * * * *
LIV is a professional data center to set up a company, with a group of professional team intimate attention to customer requirements, and provide quality services.
For more information about 'What factors do Data Center design and build need to consider when doing Structured Cabling?',please visit : http://livservices.com.hk
Address: Unit 4, 4/F., Hung Tai Industrial Building,37-39 Hung To Road, Kwun Tong, Hong Kong
Tel: +852 3106 3235